Y660 pump smartbox series products: suitable for all kinds of three phase pump water supply systems; black diamond steel box process shell, anti-oxidation anti-rust paint, three colors, perfect matching all kinds of pumps. A variety of water supply mode one-button switching, all-round protection mode for the pump to protect the escort, low noise, low vibration, to prevent all disturbance factors, 24 hours to provide you with a comfortable water experience.
| Model | Output Power | Input&output Voltage | Output Rated Curren | Adaptive Motor Power | Installation size(mm ) | Outline Dimentions(mm) | Installation Diameter | |||
| (KW) | (V) | (KW) | (A) | H | W1 | L2 | L3 | W | (mm) | |
| Y660-4T004AO | 4 | Three phase in 380V+15% | 9 | 4 | 273.5 | 74 | 294 | 131 | 173 | Φ5 |
| Y660-4T5R5AO | 5.5 | Three phase in 380V+15% | 13 | 5.5 | 273.5 | 74 | 294 | 131 | 173 | Φ5 |
| Y660-4T7R5A0 | 7.5 | Three phase in 380V+15% | 17 | 7.5 | 273.5 | 74 | 294 | 131 | 173 | Φ5 |
| Y660-4T011AO | 11 | Three phase in 380V+15% | 25 | 11 | 273.5 | 74 | 294 | 131 | 173 | Φ5 |
| Y660-4T015AO | 15 | Three phase in 380V+15% | 32 | 15 | 316.5 | 140 | 337 | 197 | 193 | Φ6 |
| Y660-4T18R5AO | 18.5 | Three phase in 380V+15% | 38 | 18.5 | 316.5 | 140 | 337 | 197 | 193 | Φ6 |
| Y660-4T022AO | 22 | Three phase in 380V+15% | 45 | 22 | 316.5 | 140 | 337 | 197 | 193 | Φ6 |
| Controlling Characteristic | |
| Starting Torque | 0.5Hz 100% |
| Speed Adjustable Range | 1:100 |
| Speed-holding precision | ±1.0% |
| Overload Capability | 150% rated current for 60s 180% rated current for 1s |
| Acceleration/deceleration Time | 0.1-3600s |
| Input&Output Parameters | |
| Start Frequency | 0.01~10.00Hz |
| Input Voltage | 220V±15% |
| Input Frequency Range | 50/60Hz,fluctuation ±5% |
| Output Voltage | 0-rated input voltage |
| Output Frequency | 0-200Hz |
| Peripheral Interface | |
| Programmable Digital lnput | 1 way of digital terminal input |
| Programmable Analog Input | V: 0-5V C ( pressure transducer ): 4-20mA |
| Running Mode | 1: Manual 2: Auto 3: Timing |
| Use Condition | |
| Installation | Installation should be executed under the conditions of no direct sunlight,dust,corrosive gas,inflammable gas,oil mist,steam and water drop |
| Altitude | Lower than 1000m,service in derated capacity above 1000m.Derate 1% capacity every 100m increase in temperature |
| Environment Temperature | -10℃-+40℃,service in derated capacity for 40℃-50℃. Derate 4% capacity every 1℃ increase in height |
| Humidity | ≤95%RH,no water condensation. |
| Vibration | <5.9m/52(0.6G) |
| Basic Functions | |
| Command Running Channel | Control terminal |
| Built-in PID | Advanced PID arithmetic to realize closed loop control system |
| Stall Speed Control | Automatically limit current and voltage at running period to prevent tripping due to frequent overcurrent or overvoltage |
| Water Shortage Protection | If the drive detects the pipe pressure is lower than the water shortage pressure set value,the system stops working automatically.After set period time,it restarts automatically for specified times.If pressure restores to normal,system works normally,otherwise,system stops automatically in case of idle running of pump and prolongs pump lifetime to the maximum extent |
| High Pressure Alarm | When pressure exceeds set pressure,it stops running automatically to avoid damage on pipe network due to high pressure |
| Automatic Energy-saving Running | Automatically lower output voltage under light loading to save energy |
| Password Setting | 4-bit password can be set with non-zero numbers,Exit password setting interface and the password will be valide in 1 minute |
| Parameters Locking | Define whether the parameter is locked in running or stopped status in case of misoperation |